 2026/11/17                                ENABLE GAS TRANSMISSION, LLC                 PAGE:     1                                                                                                                                                       
 MVRP3020-53                                   GAS SAMPLE ANALYSIS                         MVNX3020                                                                                                                                                       
                                                                                           TIME: 15:00:092                                                                                                                                                
                                                                                                                                                                                                                                                          
                                                                                                                                                                                                                                                          
         Location              Gas Day    Gravity    BTU     CO2 %    N2 %    Oxygen %   H2S %   Methane %  Ethane %  Propane %  I-Butane %  N-Butane %  Neo-Pentane %  I-Pentane %  N-Pentane %  Hexanes %  N-Heptane %  N-Octane %  N-Nonane %          
                                                                                 O2                 C1         C2        C3                                   C5                                     C6          C7           C8          C9              
  -----------------------     ----------  -------  -------  -------  -------  --------  -------  ---------  --------  ---------  ----------  ----------  -------------  -----------  -----------  ---------  -----------  ----------  ----------          
                                                                                                                                                                                                                                                          
  BAY CHECK GC @ 170610       2026/11/16  0.5829   1.02535  0.9054   00.6232  00.0000   00.0000  95.2409    03.0452   00.1563    00.0091     00.0107     00.0000        00.0030      00.0020      00.0017    00.0013      00.0006     00.0000             
  CUSTER ST @ LINE AD ST1     2026/11/16  0.5779   1.01653  0.5676   01.1966  00.0000   00.0000  95.6851    02.4827   00.0654    00.0012     00.0012     00.0000        00.0000      00.0000      00.0000    00.0000      00.0000     00.0000             
  GLENDALE CEGT TO MRT @      2026/11/16  0.5883   1.03139  0.7751   00.9621  00.0000   00.0000  93.9772    04.0850   00.1770    00.0065     00.0090     00.0000        00.0019      00.0013      00.0021    00.0015      00.0007     00.0000             
  CHANDLER ST DISCHARGE G     2026/11/16  0.5867   1.03062  0.6987   00.9779  00.0000   00.0000  94.1957    03.9371   00.1730    00.0062     00.0068     00.0000        00.0014      00.0010      00.0008    00.0006      00.0003     00.0000             
  FM 63 - Columbia GC @ 2     2026/11/16  0.6052   1.08162  0.2040   00.4200  00.0000   00.0000  90.2367    08.7610   00.3178    00.0211     00.0263     00.0000        00.0055      00.0034      00.0017    00.0013      00.0006     00.0000             
                                                                                                                                                                                                                                                          
                                                                                                                                                                                                                                                          
                                                                                                                                                                                                                                                          
 The information displayed above reflects daily average gas quality readings                                                                                                                                                                              
 taken at key locations on the EGT system.  The dates shown above are the                                                                                                                                                                                 
 dates of the readings. The readings are taken daily, and information from such                                                                                                                                                                           
 readings is posted on the first day thereafter.  If on any reading day there                                                                                                                                                                             
 are problems retrieving the data, the last reported readings will remain                                                                                                                                                                                 
 posted until such time as new readings are obtained.  Due to factors such as                                                                                                                                                                             
 equipment failure, sample contamination and human error, the information                                                                                                                                                                                 
 displayed above may not be completely accurate.